This is intelligent alarm control system which is integrated with burglarproof, fireproof, gas leak proof. It is compatible with wired and wireless alarm mode.
It used the most advanced coding technology of BUS zone and multi-bit random code-hopping technology to ensure the security & reliability of systems and avoid false alarm from interference.
Features of this alarm host:
1. 64 defense area: 8 wired, 24 wireless and 32 BUS zones.
2. 6 ways to arm and disarm the system: user code, keyfob, phone, SMS, auto timer, CMS
3. Alarm notification: When alarm occurs, user can have alarm notification by phone call, SMS
4. Can use without keypad
5. LED display on metal case, easier for user to check system information.
6. Supports 8 pcs LCD keypad and 8 wireless remotes.
7. Password: 1 installer code, 1 duress code, 15 user codes
8. CMS: 2 CMS follow me numbers, 1 account number
9. Voice Calling phone number: 4 voice numbers, voice prompting operation to answer the alarm call easy.
10. Event log: 128 event logs. events can be queried.
11. Recording: 10 seconds automatic message recording.
Other features:
1. It is with built-in GSM module and can use SMS to arm, disarm, home arm, status checking, cancel alarm etc. GSM will call the preset voice number and with voice prompting to follow to answer the alarm such as chcek alarm zone, trigger siren, cancel alarming etc.
2. GSM and PSTN priority can be set.
3. Keypad Description:
It is with Power LED, Arm LED, Disarm LED, Fault LED to indicate status.
It is with Fire button, Panic button, Medical button to send alarm signal. It is with check button to check the alarm events.
It is used to program the system.
4. BUS zone expander FC-7601
It is single zone module with working voltage DC8.5-24V.
It is with tamper inspection switch
5. It is menu guide programming
6. Entry delay time, exit delay time, siren time, ring time, power fault report delay time etc. can be set.
7. It will automatic check detectors every 3 hours (time can be set), and it will alarm when detector is lost.
8. It checks communication between alarm panel and CMS and checking interval time can be set.
9. Zone type setting:
burglar, fire alarm, 24 hours, perimeter, emergency, delay, disable
10 Response speed of wireless protection area can be set
11. Cross protection areas can be set.